Easy UPS 3S 20 kVA 400 V 3:1 UPS for internal batteries
High-efficiency 3-phase UPS that features advanced product features, competitive specifications, and robust electrical design, making business continuity easy in the data center or electrical room. This is an exceptionally easy to install, operate, maintain, and service 20 kVA UPS, ideal for small and medium businesses. Includes dust filter and conformance-coated boards for harsh environments. This UPS is for internal batteries, but is supplied without batteries, so you can easily customize the battery runtime. For battery runtime details, see the runtime charts published under the Documents tab.
Includes: Dust filter, Installation guide
Replaceable dust filters
protect the UPS in harsh environments.
Optional SNMP Card
When you purchase the SNMP card, you can monitor and manage UPS status remotely through the UPS Web interface or through EcoStruxure IT's cloud-based and on-premise software suites.
Click here for more information about EcoStruxure IT.
Wide Input Voltage Window
Saves your battery power for when you really need it - during power cuts!
Parallel capability
Multiple units can be placed in parallel to meet power capacity and redundancy requirements
Intuitive user interface
The intuitive graphical user interface allows for easy system configuration.
Straightforward installation
Including the input, output, and bypass breakers, as well as the Emergency Power Off (EPO) switch, simplifies installation planning and speeds up deployment.
Easy Loop Test
Verifies UPS performance before you connect your load, without the need for a load bank.
Easy to install fast
Quickly roll the compact and lightweight UPS into position.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
Front-access servicing
Simplifies installation and UPS maintenance while minimizing space requirements.
Max Configurable Power (Watts)
Output Voltage Distortion
Output Frequency (sync to mains)
50 Hz Sync to mains, 60 Hz Sync to mains
Overload Operation
10 minutes at 125% and 60 seconds at 150%
Output Voltage THD
< 5.5% at 100% non-linear load
Input voltage range for main operations
Input Total Harmonic Distortion
Less than 5 % for full load
Type of Input Protection Required
Input Power Factor at Full Load
End of Discharge Maximum Battery Current
End of Discharge Battery Voltage
Maximum Available Short Circuit Current
Interface Port(s)
E3S_Parallel, E3S_TempSensor
Operating Relative Humidity
0 - 95 (Non-condensing) %
Storage Relative Humidity
0 - 95 (Non-condensing) %
Audible noise at 1 meter from surface of unit
Online thermal dissipation
Approvals
CE, EAC, IEC 62040-1-1, IEC 62040-2, IEC 62040-3, IEC 62040-4, ISTA 2B, RCM
Standard warranty
1 year on-site repair or replace with factory authorized Start-Up