Menu
Your Cart

PLANET Industrial 1-Port RS232/RS422/RS485 Serial Device Server

PLANET Industrial 1-Port RS232/RS422/RS485 Serial Device Server
PLANET Industrial 1-Port RS232/RS422/RS485 Serial Device Server
  • Stock: 15-20 Ημέρες
  • Model: ICS-2100T
  • UPC: PLA-00466
  • EAN: 4711605285100

Cost-effective Solution for RS232/422/485 Serial-to-Industrial Ethernet Application

PLANET ICS-2100T Serial Device Server is specially designed to convert RS232, RS422 or RS485 serial communication to Industrial Fast Ethernet networking so as to extend the network distance efficiently and inexpensively. There is one 10/100BASE-TX RJ45 port in the ICS-2100T and its operating temperature ranges from -40 to 75 degrees C for your network needs. The ICS-2100T is a time-saving and cost-effective solution for users and system integrators to quickly transform their serial devices into the Ethernet network with no need of replacing the existing serial devices and software system.

Remote Management

As the ICS-2100T provides easy serial-to-Ethernet connectivity and connection to a TCP/IP network, the remote network system can thus be managed efficiently via its Web, telnet, and VCOM management interfaces. It supports both application and serial operation modes for alarm or IP address connection, which saves the network administrator’s time in detecting and locating network problems without visual inspection of the cabling and devices.  Multiple connection options are available for a large networking environment as well.

Stable Performance under Difficult Environments

The ICS-2100T provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curbside traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the ICS-2100T   to be placed in almost any difficult environment. 

The ICS-2100T, equipped with compact IP30 standard metal case, allows either DIN-rail or wall mounting for efficient use of cabinet space.  The ICS-2100T   also provides an integrated power supply source with a wide range of voltages (9 to 48V DC / 24V AC) ideally suitable for worldwide operation with high availability applications requiring dual or backup power inputs.

Dual Power Input for High Availability Network System

The ICS-2100T features a strong dual power input system with wide-ranging voltages (9V~48V DC / 24V AC) incorporated into customer’s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the ICS-2100T  via Power Supply 2 without any break of operation.

Effective Alarm Alert for Better Protection

The ICS-2100T comes with a Fault Alarm feature which can alert the users when there is something wrong with the Serial Device Server. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource. The ICS-2100T  provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.

    Serial Interface
    Serial Ports 1 x DB9 male for RS232 1 x 4-Pin Terminal block for RS422 / RS485
    Serial Standards RS232 / 4-wire RS422 or RS485 / 2-wire RS485
    Baud Rate (Data Rate) 50bps to 921Kbps
    Data Bits 5, 6, 7, 8
    Parity Type 1, 1.5, 2
    Stop Bit Odd, Even, None, Space, Mark
    Flow Control RTS/CTS and DTR/DSR (RS232 only) XON/XOFF
    Signals RS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND RS422: Tx+, Tx-, Rx+, Rx-, GND 4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND 2-wire RS485: Data A (+), Data B (-), GND
    Pin Assignment
    PinRS232RS422
    RS485-4W
    RS485-2W
    1DCDTxD+--
    2RxDTxD---
    3TxDRxD-Data-
    4DTRRxD+Data+
    5GNDGNDGND
    6DSR----
    7RTS----
    8CTS----
    9------
    Ethernet Interface
    Ethernet Ports 1 x RJ45
    Standard 10/100BASE-TX
    Distance 100m
    ESD Protection 6KV
    Surge Protection 2KV
    Hardware
    Installation DIN-rail kit and wall-mount ear
    Enclosure IP 30 metal
    Dimensions (W x D x H) 32 x 87.8 x 135 mm
    Weight 392g
    LED Indicators System: Power 1, Power 2, Fault, SYS TP Port: Link/Active Serial Port: Tx and Rx
    Power Requirements 9~48V DC / 24V AC, redundant power with reverse polarity protection
    Power Consumption Full Loading 9VDC: 0.35A (3.15 watts) 12VDC: 0.28A (3.36 watts) 24VDC: 0.12A (3 watts) 48VDC: 0.08A (3.84 watts)
    Connector Removable 6-pin terminal block for power input Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
    Alarm Provides one relay output for power failure Alarm relay current carry ability: 1A @ DC 24V
    Reset Button < 5 sec: System reboot > 5 sec: Factory default
    Management
    Management Interfaces Web management Telnet Console management Windows-based VCOM Utility management SNMPv1, v2c / SNMP Trap UNI-NMS monitoring PLANET Smart Discovery Utility
    IP Version IPv4 and IPv6
    Operation Mode TCP Server TCP Client UDP Client Virtual COM RFC2217 Telnet Server Pair Connection – Remote (Slave) Pair Connection – Local (Master) Modbus converter server / client
    Virtual COM Utility Platform Supports Windows-based Only:  Windows XP  Windows Server 2003  Windows 7  Windows Server 2008  Windows 8 (Must install the latest version of WinPcap)  Windows Server 2012 (Must install the latest version of WinPcap)  Windows 10
    Security Allow max. 4 accessible IP address hosts/ranges
    SNMP MIBs RFC1213 MIB-II RFC1317 RS232-like MIB
    Standards Conformances
    Regulatory Compliance FCC Part 15 Class A, CE Certification Class A
    Stability Testing IEC60068-2-32 (Free fall) IEC60068-2-27 (Shock) IEC60068-2-6 (Vibration)
    Standards IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX RFC 768 UDP RFC 793 TFTP RFC 791 IP RFC 792 ICMP RFC 854 Telnet RFC 958 NTP RFC 1591 DNS (client only) RFC 1908 SNMPv2c RFC 2068 HTTP RFC 2131 DHCP Client RFC 2732 Format for Literal IPv6 Addresses in URL's RFC 3315 DHCPv6 Client RFC 3513 IPv6 Addressing Architecture RFC 3596 DNSv6 RFC 4443 ICMPv6 EIA/TIA RS232/422/485
    Regulatory Approval RoHS
    Environment
    Operating Temperature -40 ~ 75 degrees C
    Storage Temperature -40 ~ 85 degrees C
    Humidity 5 ~ 95% (non-condensing)