Menu
Your Cart

Planet IP30 Industrial 1-Port RS232/RS422/RS485 Modbus Gateway (1 x 100BASE-FX SC, Single mode 30km, -40~75 degrees C, dual 9~48V DC, Modbus RTU/ASCII, Master/Slave )

Planet IP30 Industrial 1-Port RS232/RS422/RS485 Modbus Gateway (1 x 100BASE-FX SC, Single mode 30km, -40~75 degrees C, dual 9~48V DC, Modbus RTU/ASCII, Master/Slave )
Planet IP30 Industrial 1-Port RS232/RS422/RS485 Modbus Gateway (1 x 100BASE-FX SC, Single mode 30km, -40~75 degrees C, dual 9~48V DC, Modbus RTU/ASCII, Master/Slave )
  • ΔΙΑΘΕΣΙΜΟΤΗΤΑ: 15-20 Ημέρες
  • Κωδικός Προϊόντος: IMG-2102TS
  • EAN: 4711605285735

Διαθέσιμες Επιλογές

RS-232
RS485 RS422

Modbus TCP
Modbus RTU ASCII
75°C~-40°C
100FX Fiber Optical





Standard Industrial Modbus TCP/RTU/ASCII Network Integration

PLANET has added the Industrial Modbus TCP/IP Protocol to its easily-integrated industrial management level products that come with SCADA/HMI system and other data acquisition systems on factory floors. Moreover, the industrial IT SNMP network is upgraded to the Industrial automation Modbus TCP/IP network. PLANET industrial management level products with the Modbus TCP/IP Protocol offer flexible network connectivity solutions for the industrial automation environment.

To complete the industrial automation environment application solution, PLANET has announced a first industrial level 1-port RS232/422/485 Modbus Gateway, IMG-210xT Series, a bridge that converts between Modbus TCP/IP Protocol and Modbus RTU/ASCII Protocol. It features a wide operating temperature range from -40 to 75 degrees C and a compact but rugged IP30 metal housing. 

 

A Conversion Bridge for Flexible Network Deployment 

The IMG-210xT Series can be a conversion bridge between the equipment with the Modbus RTU/ASCII Protocol and the administrator workstations that run the Modbus TCP/IP Protocol. The RS232/422/485 serial interface of the IMG-210xT Series provides the Modbus RTU/ASCII operation mode and various baud rate options to meet the demand of integration between the Modbus TCP/IP Protocol, Modbus RTU Master/Slave Protocol and Modbus ASCII Master/Slave Protocol.

The advantage of having the IMG-210xT series is to assist users to build an industrial environment between the Modbus TCP/IP Protocol and the Modbus RTU/ASCII Protocol easily, thus offering an application solution to the industrial control equipment without Ethernet ports and the industrial control equipment can only control through an industrial PC workstation or industrial control panel. 

In addition, the effective integration solution of Modbus Ethernet devices, Modbus serial equipment or multi Modbus master / slave in an industrial hybrid network brings the following:

  • Master mode supports up to 32 TCP slave connection requests
  • Slave mode supports up to 32 TCP master connections

 

Remote Management 

The IMG-210xT series makes the connected industrial Modbus RTU/ASCII equipment become IP-based facilities and is able to connect to the Modbus TCP/IP network via its RS232/422/485 serial interface and 100BASE-FX Ethernet port. It provides a remote web management and telnet Interface for efficient remote network management.  The IMG-210xT series also provides PLANET Modbus Gateway utility tool and supports PLANET Smart Discovery utility to help network administrator to easily get the current IP subnet address information or change the IP subnet address setting of the IMG-210xT series.

 

Modbus Serial Port State Monitoring

The IMG-210xT series shows the details of the total bytes transmitted and received on the RS232/422/485 serial interface, and the detailed total number of frames transmitted and received on the remote web/telnet management interface. This function allows network administrator to check the status and statistics of the IMG-210xT series via the single RS232/422/485 serial interface.

 

Stable Performance in Hardened Environment Design

The IMG-210xT series provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb-side traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the IMG-210xT series to be placed in almost any difficult environment. 

The IMG-210xT series is equipped with a compact IP30-rated metal case that allows wall mounting for efficient use of cabinet space. The IMG-210xT series also provides an integrated power supply source with wide-ranging voltages (9 to 48V DC / 24V AC) ideally suitable for worldwide operation with high availability applications.

 

Dual Power Input for High Availability Network System

The IMG-210xT series features a strong dual power input system with wide-ranging voltages (9V~48V DC / 24V AC) incorporated into customer’s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the IMG-210xT series via Power Supply 2 without any break of operation.

    Serial Interface
    Serial PortsIMG-2105AT
    1 x DB9 male for RS232
    1 x 4-Pin Terminal block for RS422 / RS485

    IMG-2102T
    1 x DB9 male for RS232
    1 x 4-Pin Terminal block for RS422 / RS485

    IMG-2102TS
    1 x DB9 male for RS232
    1 x 4-Pin Terminal block for RS422 / RS485
    Serial StandardsRS232 / 4-wire RS422 or RS485 / 2-wire RS485
    Baud Rate (Data Rate)50bps to 921Kbps
    Data Bits5, 6, 7, 8
    Stop Bit1, 1.5, 2
    Parity TypeOdd, Even, None, Space, Mark
    Flow ControlRTS/CTS and DTR/DSR (RS232 only)
    XON/XOFF
    SignalsRS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
    RS422: Tx+, Tx-, Rx+, Rx-, GND
    4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND
    2-wire RS485: Data A (+), Data B (-), GND
    Pin AssignmentSerial Port
    PinRS232RS422
    RS485-4W
    RS485-2W
    1DCDTxD+--
    2RxDTxD---
    3TxDRxD-Data-
    4DTRRxD+Data+
    5GNDGNDGND
    6DSR----
    7RTS----
    8CTS----
    9------


    4-pin Terminal Block
    PinRS422
    RS485-4W
    RS485-2W
    1TxD+(A)--
    2TxD-(B)--
    3RxD-(B)Data-(B)
    4RxD+(A)Data+(A)
    Operation ModeRTU Master/RTU Slave/ASCII Master/ASCII Slave
    Master mode: Supports up to 32 TCP slave connection requests
    Slave mode: Supports up to 32 TCP master connection requests
    Ethernet Interface
    Ethernet PortIMG-2105AT: 1 x SFP
    IMG-2102T/ICS-2102TS: 1 x Duplex SC
    Standard100BASE-FX
    ConnectorIMG-2105AT: LC
    IMG-2102T/ICS-2102TS: Duplex SC
    Fiber ModeIMG-2105AT: Single mode or multi-mode (may vary on SFP module)
    IMG-2102T: Multi-mode
    IMG-2102TS: Single mod
    Transmission ModeFull duplex
    DistanceIMG-2105AT: 2km to 120km (may vary on SFP module)
    IMG-2102T: 2km
    IMG-2102TS: 30km
    CableIMG-2105AT:
    50 or 62.5/125μm multi-mode fiber cable
    9/125μm single-mode cable

    IMG-2102T: 50/125μm or 62.5/125μm multi-mode fiber cable

    IMG-2102TS: 9/125μm single-mode cable
    ESD Protection6KV
    Surge Protection2KV
    Hardware
    InstallationDIN-rail kit and wall-mount ear
    EnclosureIP 30 metal
    Dimensions (W x D x H)32 x 87.8 x 135 mm
    WeightIMG-2105AT: 390g
    IMG-2102T: 386g
    IMG-2102TS: 391g
    LED IndicatorsSystem: Power 1, Power 2, Fault, SYS
    SFP: Link/Active
    Serial Port: Tx and Rx
    Power Requirements9~48V DC / 24V AC, redundant power with reverse polarity protection
    Power ConsumptionIMG-2105AT:
    Full Loading
    9VDC: 0.44A (3.96 watts)
    12VDC: 0.33A (4 watts)
    24VDC: 0.17A (4.08 watts)
    48VDC: 0.1A (4.8 watts)

    IMG-2102T:
    Full Loading
    9VDC: 0.56A (5 watts)
    12VDC: 0.42A (5 watts)
    24VDC: 0.23A (5.5 watts)
    48VDC: 0.13A (6 watts)

    IMG-2102TS:
    Full Loading
    9VDC: 0.56A (5 watts)
    12VDC: 0.42A (5 watts)
    24VDC: 0.23A (5.5 watts)
    48VDC: 0.13A (6 watts)
    ConnectorRemovable 6-pin terminal block for power input
    Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
    AlarmProvides one relay output for power failure
    Alarm relay current carry ability: 1A @ DC 24V
    Reset Button< 5 sec: System reboot
    > 5 sec: Factory default
    Management
    Management InterfacesWeb management
    Telnet Console management
    Windows-based MB VCOM Utility management
    SNMPv1, v2c / SNMP Trap
    UNI-NMS monitoring
    PLANET Smart Discovery Utility
    IP VersionIPv4 and IPv6
    Operation ModeRTU Master
    RTU Slave
    ASCII Master
    ASCII Slave
    Virtual COM Utility Platform SupportsWindows-based only:
     Windows XP
     Windows Server 2003
     Windows 7
     Windows Server 2008
     Windows 8 (Must install the latest version of WinPcap)
     Windows Server 2012 (Must install the latest version of WinPcap)
     Windows 10
    Fault AlarmRecord: System log / SNMP trap
    TimeNTP
    SecurityAllow maximum 4 accessible IP address hosts/ranges
    SNMP MIBsRFC1213 MIB-II
    RFC1317 RS232-like MIB
    Standards Conformances
    Regulatory ComplianceFCC Part 15 Class A,
    CE Certification Class A
    RoHS
    Stability TestingIEC60068-2-32 (Free fall)
    IEC60068-2-27 (Shock)
    IEC60068-2-6 (Vibration)
    StandardsIEEE 802.3 10BASE-T
    IEEE 802.3u 100BASE-FX
    RFC 768 UDP
    RFC 793 TFTP
    RFC 791 IP
    RFC 792 ICMP
    RFC 854 Telnet
    RFC 958 NTP
    RFC 1591 DNS (client only)
    RFC 1908 SNMPv2c
    RFC 2068 HTTP
    RFC 2131 DHCP Client
    RFC 2732 Format for Literal IPv6 Addresses in URL's
    RFC 3315 DHCPv6 Client
    RFC 3513 IPv6 Addressing Architecture
    RFC 3596 DNSv6
    RFC 4443 ICMPv6
    EIA/TIA RS232/422/485
    Environment
    Operating Temperature-40 ~ 75 degrees C
    Storage Temperature-40 ~ 85 degrees C
    Humidity5 ~ 95% (non-condensing)