Menu
Your Cart

PLANET IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multi-mode 2km, -40~75 degrees C, dual 9~48V DC, Web, Telnet and SNMP management )

PLANET IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multi-mode 2km, -40~75 degrees C, dual 9~48V DC, Web, Telnet and SNMP management )
PLANET IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multi-mode 2km, -40~75 degrees C, dual 9~48V DC, Web, Telnet and SNMP management )
  • ΔΙΑΘΕΣΙΜΟΤΗΤΑ: In Stock
  • Κωδικός Προϊόντος: ICS-2102T
  • UPC: PLA-00514
  • EAN: 4711605285704

RS-232
RS485 RS422
WEB Management
Fiber-Optical
Redundant power AC/DC
IP 30
75°C~-40°C


Cost-effective Solution for RS232/422/485 Serial-to-Industrial Ethernet Application

PLANET ICS-210xT Serial Device Server series is specially designed to convert RS232, RS422 or RS485 serial communication to Industrial Fast Ethernet networking so as to extend the network distance efficiently and inexpensively. There is one 100BASE-FX single-mode/multi-mode media available in the ICS-210xT series and its operating temperature ranges from -40 to 75 degrees C for your network needs. The ICS-210xT series is a time-saving and cost-effective solution for users and system integrators to quickly transform their serial devices into the Ethernet network with no need of replacing the existing serial devices and software system. 

 

 

Efficiently Extend Network Distance

The ICS-210xT series especially equips one fiber interface (100BASE-FX, choice of fiber-connector from SC / LC, multi-mode / single-mode fiber) and is able to extend the distance of deploying serial equipment and hosts. Users are able to select fiber-optic cables (based on distance) provided for distance extension from 2 kilometers (via multi-mode fiber) to 60 kilometers (via single-mode fiber) or longer.

 

 

Remote Management 

As the ICS-210xT series provides easy serial-to-Ethernet connectivity and connection to a TCP/IP network, the remote network system can thus be managed efficiently via its Web, telnet, and VCOM management interfaces. It supports both application and serial operation modes for alarm or IP address connection, which saves the network administrator’s time in detecting and locating network problems without visual inspection of the cabling and devices. Multiple connection options are available for a large networking environment as well.

Stable Performance under Difficult Environments

The ICS-210xT series provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curbside traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the ICS-210xT series to be placed in almost any difficult environment. 

The ICS-210xT series with compact IP30 standard metal case allows either DIN-rail or wall mounting for efficient use of cabinet space. The ICS-210xT series also provides an integrated power supply source with a wide range of voltages (9 to 48V DC/24V AC) ideally suitable for worldwide operation with high availability applications requiring dual or backup power inputs.

 

Dual Power Input for High Availability Network System

The ICS-210xT series features a strong dual power input system with wide-ranging voltages (9V~48V DC/24V AC) incorporated into customer’s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the ICS-210xT series via Power Supply 2 without any break of operation.

 

Effective Alarm Alert for Better Protection

The ICS-210xT series comes with a Fault Alarm feature which can alert the users when there is something wrong with the Serial Device Server. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource. The ICS-210xT series provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.

    Serial Interface
    Serial PortsICS-2105AT
    1 x DB9 male for RS232
    1 x 4-Pin Terminal block for RS422 / RS485

    ICS-2102T
    1 x DB9 male for RS232
    1 x 4-Pin Terminal block for RS422 / RS485

    ICS-2102TS
    1 x DB9 male for RS232
    1 x 4-Pin Terminal block for RS422 / RS485
    Serial StandardsRS232 / 4-wire RS422 or RS485 / 2-wire RS485
    Baud Rate (Data Rate)50bps to 921Kbps
    Data Bits5, 6, 7, 8
    Parity Type1, 1.5, 2
    Stop BitOdd, Even, None, Space, Mark
    Flow ControlRTS/CTS and DTR/DSR (RS232 only)
    XON/XOFF
    SignalsRS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
    RS422: Tx+, Tx-, Rx+, Rx-, GND
    4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND
    2-wire RS485: Data A (+), Data B (-), GND
    Pin AssignmentSerial Port
    PinRS232RS422
    RS485-4W
    RS485-2W
    1DCDTxD+--
    2RxDTxD---
    3TxDRxD-Data-
    4DTRRxD+Data+
    5GNDGNDGND
    6DSR----
    7RTS----
    8CTS----
    9------


    4-pin Terminal Block
    PinRS422
    RS485-4W
    RS485-2W
    1TxD+(A)--
    2TxD-(B)--
    3RxD-(B)Data-(B)
    4RxD+(A)Data+(A)
    Ethernet Interface
    Ethernet PortsICS-2105AT: 1 x SFP
    ICS-2102T/ICS-2102TS: 1 x Duplex SC
    Standard100BASE-FX
    ConnectorICS-2105AT: LC
    ICS-2102T/ICS-2102TS: Duplex SC
    Fiber ModeICS-2105AT: Single mode or multi-mode (may vary on SFP module)
    ICS-2102T: Multi-mode
    ICS-2102TS: Single mod
    Transmission ModeFull duplex
    DistanceICS-2105AT: 2km to 120km (may vary on SFP module)
    ICS-2102T: 2km
    ICS-2102TS: 30km
    CableICS-2105AT:
    50 or 62.5/125μm multi-mode fiber cable
    9/125μm single-mode cable

    ICS-2102T: 50/125μm or 62.5/125μm multi-mode fiber cable

    ICS-2102TS: 9/125μm single-mode cable
    ESD Protection6KV
    Surge Protection2KV
    Hardware
    InstallationDIN-rail kit and wall-mount ear
    EnclosureIP 30 metal
    Dimensions (W x D x H)32 x 87.8 x 135 mm
    WeightICS-2105AT: 390g
    ICS-2102T: 386g
    ICS-2102TS: 391g
    LED IndicatorsSystem: Power 1, Power 2, Fault, SYS
    SFP: Link/Active
    Serial Port: Tx and Rx
    Power Requirements9~48V DC / 24V AC, redundant power with reverse polarity protection
    Power ConsumptionICS-2105AT:
    Full Loading
    9VDC: 0.44A (3.96 watts)
    12VDC: 0.33A (4 watts)
    24VDC: 0.17A (4.08 watts)
    48VDC: 0.1A (4.8 watts)

    ICS-2102T:
    Full Loading
    9VDC: 0.56A (5 watts)
    12VDC: 0.42A (5 watts)
    24VDC: 0.23A (5.5 watts)
    48VDC: 0.13A (6 watts)

    ICS-2102TS:
    Full Loading
    9VDC: 0.56A (5 watts)
    12VDC: 0.42A (5 watts)
    24VDC: 0.23A (5.5 watts)
    48VDC: 0.13A (6 watts)
    ConnectorRemovable 6-pin terminal block for power input
    Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
    AlarmProvides one relay output for power failure
    Alarm relay current carry ability: 1A @ DC 24V
    Reset Button< 5 sec: System reboot
    > 5 sec: Factory default
    Management
    Management InterfacesWeb management
    Telnet Console management
    Windows-based VCOM Utility management
    SNMPv1, v2c / SNMP Trap
    UNI-NMS monitoring
    PLANET Smart Discovery Utility
    IP VersionIPv4 and IPv6
    Operation ModeTCP Server
    TCP Client
    UDP Client
    Virtual COM
    RFC2217
    Telnet Server
    Pair Connection – Remote (Slave)
    Pair Connection – Local (Master)
    Modbus converter server / client
    Virtual COM Utility Platform SupportsWindows-based only:
     Windows XP
     Windows Server 2003
     Windows 7
     Windows Server 2008
     Windows 8 (Must install the latest version of WinPcap)
     Windows Server 2012 (Must install the latest version of WinPcap)
     Windows 10
    SecurityAllows maximum 4 accessible IP address hosts/ranges
    SNMP MIBsRFC1213 MIB-II
    RFC1317 RS232-like MIB
    Standards Conformances
    Regulatory ComplianceFCC Part 15 Class A,
    CE Certification Class A
    RoHS
    Stability TestingIEC60068-2-32 (Free fall)
    IEC60068-2-27 (Shock)
    IEC60068-2-6 (Vibration)
    StandardsIEEE 802.3 10BASE-T
    IEEE 802.3u 100BASE-FX
    RFC 768 UDP
    RFC 793 TFTP
    RFC 791 IP
    RFC 792 ICMP
    RFC 854 Telnet
    RFC 958 NTP
    RFC 1591 DNS (client only)
    RFC 1908 SNMPv2c
    RFC 2068 HTTP
    RFC 2131 DHCP Client
    RFC 2732 Format for Literal IPv6 Addresses in URL's
    RFC 3315 DHCPv6 Client
    RFC 3513 IPv6 Addressing Architecture
    RFC 3596 DNSv6
    RFC 4443 ICMPv6
    EIA/TIA RS232/422/485
    Environment
    Operating Temperature-40 ~ 75 degrees C
    Storage Temperature-40 ~ 85 degrees C
    Humidity5 ~ 95% (non-condensing)