Menu
Your Cart

PLANET IP30 Industrial 1-Port RS232/RS422/RS485 Modbus Gateway (1 x 100BASE-FX SC, Multi-mode 2km, -40~75 degrees C, dual 9~48V DC, Modbus RTU/ASCII, Master/Slave )

PLANET IP30 Industrial 1-Port RS232/RS422/RS485 Modbus Gateway (1 x 100BASE-FX SC, Multi-mode 2km, -40~75 degrees C, dual 9~48V DC, Modbus RTU/ASCII, Master/Slave )
PLANET IP30 Industrial 1-Port RS232/RS422/RS485 Modbus Gateway (1 x 100BASE-FX SC, Multi-mode 2km, -40~75 degrees C, dual 9~48V DC, Modbus RTU/ASCII, Master/Slave )
  • ΔΙΑΘΕΣΙΜΟΤΗΤΑ: 15-20 Ημέρες
  • Κωδικός Προϊόντος: IMG-2102T
  • EAN: 4711605285728

Διαθέσιμες Επιλογές

RS-232
RS485 RS422

Modbus TCP
Modbus RTU ASCII
75°C~-40°C
100FX Fiber Optical





Standard Industrial Modbus TCP/RTU/ASCII Network Integration

PLANET has added the Industrial Modbus TCP/IP Protocol to its easily-integrated industrial management level products that come with SCADA/HMI system and other data acquisition systems on factory floors. Moreover, the industrial IT SNMP network is upgraded to the Industrial automation Modbus TCP/IP network. PLANET industrial management level products with the Modbus TCP/IP Protocol offer flexible network connectivity solutions for the industrial automation environment.

To complete the industrial automation environment application solution, PLANET has announced a first industrial level 1-port RS232/422/485 Modbus Gateway, IMG-210xT Series, a bridge that converts between Modbus TCP/IP Protocol and Modbus RTU/ASCII Protocol. It features a wide operating temperature range from -40 to 75 degrees C and a compact but rugged IP30 metal housing. 

 

A Conversion Bridge for Flexible Network Deployment 

The IMG-210xT Series can be a conversion bridge between the equipment with the Modbus RTU/ASCII Protocol and the administrator workstations that run the Modbus TCP/IP Protocol. The RS232/422/485 serial interface of the IMG-210xT Series provides the Modbus RTU/ASCII operation mode and various baud rate options to meet the demand of integration between the Modbus TCP/IP Protocol, Modbus RTU Master/Slave Protocol and Modbus ASCII Master/Slave Protocol.

The advantage of having the IMG-210xT series is to assist users to build an industrial environment between the Modbus TCP/IP Protocol and the Modbus RTU/ASCII Protocol easily, thus offering an application solution to the industrial control equipment without Ethernet ports and the industrial control equipment can only control through an industrial PC workstation or industrial control panel. 

In addition, the effective integration solution of Modbus Ethernet devices, Modbus serial equipment or multi Modbus master / slave in an industrial hybrid network brings the following:

  • Master mode supports up to 32 TCP slave connection requests
  • Slave mode supports up to 32 TCP master connections

 

Remote Management 

The IMG-210xT series makes the connected industrial Modbus RTU/ASCII equipment become IP-based facilities and is able to connect to the Modbus TCP/IP network via its RS232/422/485 serial interface and 100BASE-FX Ethernet port. It provides a remote web management and telnet Interface for efficient remote network management.  The IMG-210xT series also provides PLANET Modbus Gateway utility tool and supports PLANET Smart Discovery utility to help network administrator to easily get the current IP subnet address information or change the IP subnet address setting of the IMG-210xT series.

 

Modbus Serial Port State Monitoring

The IMG-210xT series shows the details of the total bytes transmitted and received on the RS232/422/485 serial interface, and the detailed total number of frames transmitted and received on the remote web/telnet management interface. This function allows network administrator to check the status and statistics of the IMG-210xT series via the single RS232/422/485 serial interface.

 

Stable Performance in Hardened Environment Design

The IMG-210xT series provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb-side traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the IMG-210xT series to be placed in almost any difficult environment. 

The IMG-210xT series is equipped with a compact IP30-rated metal case that allows wall mounting for efficient use of cabinet space. The IMG-210xT series also provides an integrated power supply source with wide-ranging voltages (9 to 48V DC / 24V AC) ideally suitable for worldwide operation with high availability applications.

 

Dual Power Input for High Availability Network System

The IMG-210xT series features a strong dual power input system with wide-ranging voltages (9V~48V DC / 24V AC) incorporated into customer’s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the IMG-210xT series via Power Supply 2 without any break of operation.

Serial Interface
Serial PortsIMG-2105AT
1 x DB9 male for RS232
1 x 4-Pin Terminal block for RS422 / RS485

IMG-2102T
1 x DB9 male for RS232
1 x 4-Pin Terminal block for RS422 / RS485

IMG-2102TS
1 x DB9 male for RS232
1 x 4-Pin Terminal block for RS422 / RS485
Serial StandardsRS232 / 4-wire RS422 or RS485 / 2-wire RS485
Baud Rate (Data Rate)50bps to 921Kbps
Data Bits5, 6, 7, 8
Stop Bit1, 1.5, 2
Parity TypeOdd, Even, None, Space, Mark
Flow ControlRTS/CTS and DTR/DSR (RS232 only)
XON/XOFF
SignalsRS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS422: Tx+, Tx-, Rx+, Rx-, GND
4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND
2-wire RS485: Data A (+), Data B (-), GND
Pin AssignmentSerial Port
PinRS232RS422
RS485-4W
RS485-2W
1DCDTxD+--
2RxDTxD---
3TxDRxD-Data-
4DTRRxD+Data+
5GNDGNDGND
6DSR----
7RTS----
8CTS----
9------


4-pin Terminal Block
PinRS422
RS485-4W
RS485-2W
1TxD+(A)--
2TxD-(B)--
3RxD-(B)Data-(B)
4RxD+(A)Data+(A)
Operation ModeRTU Master/RTU Slave/ASCII Master/ASCII Slave
Master mode: Supports up to 32 TCP slave connection requests
Slave mode: Supports up to 32 TCP master connection requests
Ethernet Interface
Ethernet PortIMG-2105AT: 1 x SFP
IMG-2102T/ICS-2102TS: 1 x Duplex SC
Standard100BASE-FX
ConnectorIMG-2105AT: LC
IMG-2102T/ICS-2102TS: Duplex SC
Fiber ModeIMG-2105AT: Single mode or multi-mode (may vary on SFP module)
IMG-2102T: Multi-mode
IMG-2102TS: Single mod
Transmission ModeFull duplex
DistanceIMG-2105AT: 2km to 120km (may vary on SFP module)
IMG-2102T: 2km
IMG-2102TS: 30km
CableIMG-2105AT:
50 or 62.5/125μm multi-mode fiber cable
9/125μm single-mode cable

IMG-2102T: 50/125μm or 62.5/125μm multi-mode fiber cable

IMG-2102TS: 9/125μm single-mode cable
ESD Protection6KV
Surge Protection2KV
Hardware
InstallationDIN-rail kit and wall-mount ear
EnclosureIP 30 metal
Dimensions (W x D x H)32 x 87.8 x 135 mm
WeightIMG-2105AT: 390g
IMG-2102T: 386g
IMG-2102TS: 391g
LED IndicatorsSystem: Power 1, Power 2, Fault, SYS
SFP: Link/Active
Serial Port: Tx and Rx
Power Requirements9~48V DC / 24V AC, redundant power with reverse polarity protection
Power ConsumptionIMG-2105AT:
Full Loading
9VDC: 0.44A (3.96 watts)
12VDC: 0.33A (4 watts)
24VDC: 0.17A (4.08 watts)
48VDC: 0.1A (4.8 watts)

IMG-2102T:
Full Loading
9VDC: 0.56A (5 watts)
12VDC: 0.42A (5 watts)
24VDC: 0.23A (5.5 watts)
48VDC: 0.13A (6 watts)

IMG-2102TS:
Full Loading
9VDC: 0.56A (5 watts)
12VDC: 0.42A (5 watts)
24VDC: 0.23A (5.5 watts)
48VDC: 0.13A (6 watts)
ConnectorRemovable 6-pin terminal block for power input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
AlarmProvides one relay output for power failure
Alarm relay current carry ability: 1A @ DC 24V
Reset Button< 5 sec: System reboot
> 5 sec: Factory default
Management
Management InterfacesWeb management
Telnet Console management
Windows-based MB VCOM Utility management
SNMPv1, v2c / SNMP Trap
UNI-NMS monitoring
PLANET Smart Discovery Utility
IP VersionIPv4 and IPv6
Operation ModeRTU Master
RTU Slave
ASCII Master
ASCII Slave
Virtual COM Utility Platform SupportsWindows-based only:
 Windows XP
 Windows Server 2003
 Windows 7
 Windows Server 2008
 Windows 8 (Must install the latest version of WinPcap)
 Windows Server 2012 (Must install the latest version of WinPcap)
 Windows 10
Fault AlarmRecord: System log / SNMP trap
TimeNTP
SecurityAllow maximum 4 accessible IP address hosts/ranges
SNMP MIBsRFC1213 MIB-II
RFC1317 RS232-like MIB
Standards Conformances
Regulatory ComplianceFCC Part 15 Class A,
CE Certification Class A
RoHS
Stability TestingIEC60068-2-32 (Free fall)
IEC60068-2-27 (Shock)
IEC60068-2-6 (Vibration)
StandardsIEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-FX
RFC 768 UDP
RFC 793 TFTP
RFC 791 IP
RFC 792 ICMP
RFC 854 Telnet
RFC 958 NTP
RFC 1591 DNS (client only)
RFC 1908 SNMPv2c
RFC 2068 HTTP
RFC 2131 DHCP Client
RFC 2732 Format for Literal IPv6 Addresses in URL's
RFC 3315 DHCPv6 Client
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNSv6
RFC 4443 ICMPv6
EIA/TIA RS232/422/485
Environment
Operating Temperature-40 ~ 75 degrees C
Storage Temperature-40 ~ 85 degrees C
Humidity5 ~ 95% (non-condensing)